DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1363S-SYN-PT (Speech Synthesis Port)
9
c. A transient error that does not cause an alar m can occasionally oc cur
duri ng a SPE, TDM BU S, or Tone Cloc k inte rch ange . Test th e por t and
follow the instructions for conferenc e Test (#7).
d. This error is not service-affecting and no action is required.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table be low when
inspecting errors in the sy stem. By clearing error cod es associated with the
NPE
Crosstalk Test,
for example, you may also clear errors gene rated from other tests
in the testing sequenc e.
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the se lected
time slot and never crosses over to time slots rese rved for other connections. If
the NPE is not working correctly, one-way and noisy connections may oc cur. This
test is usually only part of a port’s Long Test Sequence and takes about 20 to 30
seconds to comp lete.
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive, ND = Non-d estructive
Speech Synthesis PSS Handshake Test (#168) X X ND
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Speech Synthesis DTMF Receiver Test (#163) X ND
Speech Synthesis Memory Test (#166) X X ND
Speech Synthesis DSP Tone Test (#165) X X ND
Speech Synthesis SSD Inquiry Test (#167) X X ND
Speech Synthesis DTMF Receiver Inquiry Test (#164) X X ND
Speech Synthesis Parameter Update Test (#169) X X ND