DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-710DUP-CHL (Duplication Interface)

9
Memory Shadowing Disable Test (#872)
This test is destructive.

This test verifies the correct operation of the interrup t that indicate when

shadowing has been tur ned off (disallowed) b y the standby Processor

Table 9-275. Test #872 Memory Shadowing Disable Test
Error
Code Test
Result Description/ Recommendation
1321 ABORT The faceplate switches on the Duplication Interface circuit pac ks are not set to
auto.
1. If the switches are locked because you are using a replac ement procedure,
continue with this procedure to the step that directs you to unlock the active
SPE by mov ing b oth sw itche s to auto. The next step using the test
duplication-interface long clear should not abort with this error code.
2. If the switches are locked and a replacement procedure is not being used,
start with st ep 6 o f the SPE Du p lic ation C hanne l Comp onent Replac emen t
procedure for the standby Duplication Interface Circ uit pack at the end of
this DUP-CHL section to avoid an undesired interchange when unlocking
the active SPE.
3. If this same abort is received with both switches in auto, Replace
Duplication Interface components starting with the standby Dup lic ation
Interface circuit pack. Use SPE Duplication Channel Component
Replacement proc edures at the end of this DUP-CHL sec tion. In addition t o
looking for failures, also check for the absence of this 1321 abort code
when testing after the procedure directs setting the switches to auto after a
component replacement.
Continued on next page