DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-40ALARM-PT (ALARM PORT)

9
ALARM-PT (ALARM PORT)

The Alarm Port MO provides on-board maintenanc e for an analog line port that is

administered as an external d evice alarm port. Test are provided to verify the

analog line ports ab ility to detect an external devic e alarm. The external device

alarm (EXT-DEV) MO is used for the off-board external device alarm.

Error Log Entries and Test to Clear Values
Notes:

a. This is a software audit error that does not indic ate any hardware

malfunction. Run Short Test Sequence and investigate errors.

MO Name (in
Alarm Log) Alarm
Level Initial Command to
Run1
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
ALARM-PT MIN test port UUCSSpp l Alarm-Port
ALARM-PT WRN test port UUCSSpp sh Alarm-Port

Table 9-16. 8-Port Analog Line Error Log Entries

Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures
0 Any Any Any test port UUCSSpp sh r 1
15 (a) Any Audits and
Updates Test
(#36)
18 0 busy-out station
extension
WARNIN
GOFF release station
extension
130 (b) None WARNIN
GON test p ort UUCSSpp sh
769 Battery Feed
Test (#35) MINIOR ON test port UUCSSpp sh r 2