DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1137OPS-LINE (DS1 Off Premises Station Line)

9
DS1 OPS Switchhook Inquiry Test (#312)

This test initiates the Switchhook Audit Test. The test queries the switchhook state

of the Off-Premises-Station in switch software. If the state in switch software

disagrees with the state on the DS1 Interface c ircuit pack, then the state in the

switch software is updated to match the state on the DS1 Interface circ uit pack

Table 9-452. TEST #312 DS1 OPS Switchhook Inquiry Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use the status station
command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT Test failed due to incompatible configuration administered in station
administration.
1. Using the display station command, verify that the station is not the 24th
port of the DS1 Interface c ircuit pack while c ommon channel signaling is
specified. Use t he display ds1 command to check the signaling type of
the DS1 circuit pack.
1006 ABORT The test was aborted because the station is out of service. This condition may
be accompanied by an error typ e 18 entry in the error log. You may want to
determine why the station was taken out of service. (When stations are taken
out of service by maintenance software, the problems that led up to that must
be cleared.)
1. Use the status station command to check the state of the port. If the port
is indeed out of service, enter the release station command to bring the
station back into service.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD/UDS1-BD errors in Hardware Error Log. If present, refer
to the appropriate DS1-BD/UDS1-BD (DS1/UDS1 Interface Circuit Pack)
Maintenance documentation.
2. Retry the command.
Continued on next page