DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-401CLAN-BD (Control LAN Circuit Pack)

9
Congestion Query Test (#600)

This non-destructive test queries the numb er of used buffers to determi ne if the

CLAN circuit pac k is congested.

Normal call handling resum es when the CLAN circuit pack has rec overed from

congestion.

2012 ABORT Could not allocate the necessary system resources to run test.
2100 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
FAIL Circuit pack has detected a failure of the Packet Interface Test (#598).
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the test continues to fail, replace the circuit pack.
PASS The Packet Interface Test (#598) passed.
If: Then:
Used buffers are, or are nearly,
exhausted, The test fails
The test fails, The switch redirects outgoing calls to
another available CLAN, and denies new
incoming calls
Table 9-169. TEST #600 Congestion Query Test
Error
Code Test
Result Description/ Recommendation
2000 ABORT Did not receive circuit p ack test response within the allowable time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the test fails again, replace the circuit pack.
Continued on next page
Table 9-168. TEST #598 Packet Interface Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page