DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-122ANNOUNCE

9
ANNOUNCE Error Code Aux Data
Table 9-49. ANNOUNCE Aux Data and Repair Actions
Aux
Data Description/Recommendation
30001
through
30054
Disk/Tape errors Check and resolve errors and alarms
32001 Internal system error
Check other ANNOUNCE errors and take corrective action. If there are no other
ANNOUNCE errors:
1. Retry the command at 3 minute intervals a maximum of 3 times.
2. Try the save/restore announcement command.
32002 Announcement ci rcuit pack in use.
1. Retry the command at 2-minute intervals a maximum of 3 times.
2. Try the save/restore announcement command.
32003 Announcement po rt in use.
1. Wait for all Announcement ports to become available.
2. Enter the save/restore announcement command.
32004 No announcements on board. There are no announcements recorded on the
announcement circuit pack. The save announcement command is not allowed to
prevent the destroying of the announcement file on tape.
32005 Integrated announcement board not present. The announcement circuit pac k is not
inserted, or it is defective.
1. Enter the list config command to check for the presence of the board in the
system.
2. If the Announcement circuit pack is present, use the test board UUCSS command
to check the status of the Announcement circuit pack.
32006 Announcement data module not available.
1. Use the status data-module command to check the status of the announcement
data module.
32007 Announcement data module out of service.
1. Use the status data-module command to check the status of the announcement
data module.
32008 Announcement data being saved or loaded.
1. Retry the command at two-minute intervals a maximum of three times.
2. If the save/restore announcement command fails, escalate the problem.
Continued on next page