DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1333PPP-PT (Control LAN Packet/Port)

9
Session Status Test (#1286)

This no n-de struc tive test d eter mine s the s tatus of all PPP port sessi ons. Th is tes t

queries the system software on port session status.

1007 FAIL Ping to the destination failed due to the destination down.
1. Verify that at least one destination reachable through this port is up.
2. Once verified, test the port (test port UUCSSpp) and verify TCP/IP
Ping Test (#1281) passes.
PASS TCP/IP Ping Test (#1281) is successful.
If the system software indicates that: Then the switch:
All port sessions are up (ALL UP) Raises no alarm, or retires alarm
Some port sessions are up (SOME UP) Raises MINOR alarm
All port sessions are down (ALL DOWN) Raises MINOR alarm
Table 9-521. TEST #1286 Session Status Test
Error
Code Test
Result Description/ Recommendation
1124 ABORT ppp link is not enabled.
1. Ver i fy that the ppp link i s enable d ( status port UUCSSpp, status link
n
,
or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
1125 ABORT PPP link not in service.
1. Verify whether PPP link is in service (status port UUCSSpp or status
link n).
2. If the PPP link is not in service, release the link ( release link n or release
port UUCSSpp).
3. Repeat the test.
Continued on next page
Table 9-520. TEST #1281 TCP/IP Ping Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page