Remote Loop-Around Test (#869)
This test is destructive.

This test writes a word to a memory address on th e active SPE that is inverted

and is looped b ack by the standb y Duplication Interfac e circuit.

Table 9-273. TEST #869 Remote Loop-Around Test
Error
Code Test
Result Description/ Recommendation
1321 ABORT The faceplate switches on the Dup lication Interface circuit pac ks are not set to
auto.
1. If the switches are locked because you are using a replacement
procedure, continue with this procedure to the step that directs you to
unlock the active SPE by moving both switches to auto. The next step
using the test duplication-interface long clear should not abort with this
error code.
2. If the switches are locked and a replacement p rocedure is not being used,
start with step 6 of the SPE Duplication Channel Component Replacement
procedure for the standby
3. Duplication Interface Circuit pac k at the end of this DUP-CHL section to
avoid an und esire d int erch ange when un lock ing t he ac t ive SPE. I f this
same abort is received with both switches in auto, Replace Duplic ation
Interface components starting with the standby Duplication Interface
circuit pack. Use SPE Duplication Channel Component Replacement
procedures at the end of this DUP-CHL section. In addition to looking for
failures, also check for the absence of this 1321 abort code when testing
after the procedure d irects setting the sw itches to auto after a component
replacement.
1405 ABORT This test did not run because the Duplication Channel was busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1411 ABORT This test did not run because the standby Duplic ation Interface circuit pack
cannot be detected as being plugged in by the software.
1. If this abort continues to occur, the standb y SPE may not have initialized
properly. Use the lock-and -power-down p rocedure desc ribed in Chapt er 5
to power down and power up the standby SPE, but don’t replace any
circuit packs.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.