9-274ATM-TRK (Circuit Emulation Service Circuit Pack)

9
ATM Board Error Query Test (#1259)

This non-destructive ATM Error Query Test retrieves the most severe, active, on-

and off-board prob lem from the ATM-TRK circuit pack’s firmware and increments

error counts in the Error Log.

The test passes if there are no errors and fails otherwise. A p assing test clears

the software counters; a failure increments the c ounter associated with the

problem that caused the failure and clears the others.

1 FAIL The circuit pack failed to reset
2 FAIL The circuit pack failed to restart.
1. Retry command.
2. If the problem persists, replace the ATM-TRK circuit pack.
PASS The ATM-TRK circuit pack is successfully reset.
0NO
BOARD No board detected.
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
and perform the appropriate repair, if needed .
2. Ensure that the board is properly translated and inserted.
3. Check for Error 1538 (hyperactivity). If hyperactive, run reset board
UUCSS.
4. Run the test again. If it fails, replace the ATM-TRK circuit pack, and
retest.
Table 9-124. ATM Board Error Query Test (#1259)
Error
Code Test
Result Description/ Recommendation
2000 ABORT Test request timed out.
2031 ABORT SCD failure. Unable to sent down-link message.
2100 ABORT Could not allocate needed system resources.
2500 ABORT Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
Continued on next page
Table 9-123. ATM Board Reset (#1256) — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page