DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-514DIG-LINE (Digital Line)

9
DIG-LINE Station Lamp Updates Test (#16)

This test lights all lamps on the terminal as sp ecified. The lamp upd ates will run

only if the station is in-service. The status of the station is c hecked and the lamp

updates are block ed from taking place i f the station is not in the in-service state.

This test does not affect the status of the Message Waiting lamp.

PASS Voice and Control Channel Local Loop test passed. All channels are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to a
maximum of 10 times to make sure it continues to pass.
2. If complaints persist (noisy connections for voice, c orrup ted data for data
transfer), examine the station, connections, and wiring.
Table 9-210. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (p ort busied out) for th is port. If this
error type is present, then rel e ase the port via the release station
<extension> command and run the test again.
2. Make sure that the termin al is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
3 ABORT Station may be in ready-for-service or out-of-service state.
1. Use status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-209. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page