Alarms, Errors, and Troubleshooting

5-29ATM Tips

5
Table 5-6 shows the various LEDs on the A500 ATM switch and the meanings of the different states.
- Slow blink - Board insertion has not yet completed.
- Steady on - Running maintenance tests. May appear to be blinking
if several short tests are run one after anothe r.
Steady on - - Hardware alarm. Does not nec essarily take the TN230X
out of service, for example, if one of the 24 DSPs fails
diagnostics.
Table 5-6. A500 LED Quick Reference
Component Label Color State Meaning
Switch
Proces sor
Board
LK Green Intermittent
blink Normal state. T raffic is being sent or received
over the Ethernet LAN link.
RX Green Steady on Normal state. Carrier is received over the
Ethernet LAN link.
DIAG Green Off Normal state.
NBOOT Green Off Normal state.
MGT Green Off Normal state.
RUN Green Steady on Normal state. The switch processor is
running.
PWR Green Steady on Normal state. The switch processor board is
powere d up.
VOLT Yellow Off Normal state
TEMP Yellow Off Normal state
FAN Yellow Off Normal state
SYSERR Yellow Off N ormal s tate
FAULT Yellow Off Normal state
Switch Fabri c
Board PWR Green Steady on Normal state. The switch fabric board is
powere d up.
Continued on next page
Table 5-5. TN230X LED referenceContinuedLED color InterpretationRed Green Yellow