DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Alarms, Errors, and Troubleshooting

5-38ATM Tips

5

Figure 5-15. Screen output for display atm pnc 1 with End System Identifiers

Figure 5-16. Screen output for display atm pnc 2 with End System Identifiers

A500 Administration

Is the A500 administered correctly?

1. Enter show signaling summary on the A500 console. Figure 5-17 shows

the screen output.

display atm pnc 1
ATM PNC
Connection Number: 1
A - PNC
Location: 01B02
Name:
Address Format: E.164 ATM Private
AFI: 45
E.164: 0001013035381053
HO-DSP: 00000000
ESI: 000000000011
SEL: 00
display atm pnc 2
ATM PNC
Connection Number: 2
A - PNC
Location: 02A01
Name:
Address Format: E.164 ATM Private
AFI: 45
E.164: 0001013035381053
HO-DSP: 00000000
ESI: 000000000012
SEL: 00