DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Architecture
1-3What’s new for R7r
1
These fields are shown in bold for reference only.
Figure 1-2. Change system-parameters security form
!WARNING:

Do not change any of these fields to y.

ATM
The DEFINITY ECS can interface with an Asynchronous Transfer Mode (ATM)
switch array to allow:
Replacement of the G3r Center Stage Switch
PNC-WAN
Customers to merge voice and data networks
See ATM-EI and related Maintenance Objects
Circuit Emulation Service (CES) or ATM trunking
IP Trunking
The DEFINITY ECS interfaces through the new TN802 circuit p ack to an Internet
connection to provid e Internet telephony servic es.
change system-parameters security Page 2 of 2
SECURITY-RELATED SYSTEM-PARAMETERS
SECURITY VIOLATION NOTIFICATION PARAMETERS
SVN Station Security Code Violation Notification Enabled? n
Originating Extension: ______ Referral Destination? n
Station Security Code Threshold: 10 Time Interval: 0:03
Announcement Extension: ______
STATION SECURITY CODE VERIFICATION PARAMETERS
Minimum Station Security Code Length: 4
Security Code for Terminal Self-Administration Required? y
SOFTLOCK PARAMETERS
SYSAM-LCL? n SYSAM-RMT? n
MAINT? n SYS-PORT? n