DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-197ATM-EI (Expansion Interface Circuit Pack)

9
Figure 9-6. ATM Board DSP Test (#1258)
Table 9-84. ATM Board DSP Test (#1258)
Error Code Test
Result Description/ Recommendation
1002 ABORT The system could not allocate timeslots for the test. The system may
be under heavy traffic conditions or it may have timeslots out of
service due to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, retry the command at 1-minute intervals a maximum of 3
times.
1003 ABORT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of tone detectors present, or some
tone detectors may be out of service.
1. Enter display errors and resolve any TTR-LEV errors. Even if
there are not TTR-LEV errors, there may not be a tone detector
available on the network that contains the circuit pack being
tested. Verify that there is at least one tone detector on the
network. If not, this test always aborts for this ATM-E I circuit pack
and does not harm the sy s tem.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 3 times.
Continued on next page
Toneclock
Tonedetector
PNCmode
iodfatdsAWF 040699
DSP1
DSP24
TDMbus
(PNX)
ATM
circuit
pack