DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-555DISK (MSS Disk Circuit Pack)

9
Disk Diagnostic Test (#813)

The Disk Diagnostic test causes the Host Ad apter to send a SCSI send

diagnostics command to the DISK Drive circuit p ack. This initiates a set of

device-dep endent self-tests that are run as a unit. Failures can be for multip le

1350 ABORT Could not run the test on the Standby SPEShadowing not enabled.
1. When the standby is restored to service (use status spe to determine state
of standby) retry the command.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2500 ABORT Could not run the test on the Standby SPEInternal software error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
5102 ABORT Could not allocate the Mass Storage System to run this test
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, verify that the daily translation-save operation
is not in progress (issue the display system-parameters maintenance
command to display the time for scheduled maintenance and the "y/n"
option for saving translation daily).
NO
BOARD The disk has been placed in the "uninstalled" state.
1. Verify that the disk drive is fully inserted and powered up.
2. Attempt a demand reset of the disk.
1FAIL At least one of the firmware error counters was non-zero.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Disk circuit pack, issue the reset
disk command and perform the restore disk command. This will take up
to 1 hour for a complete restore.
3. If the test continues to fail, replace the MSSNET circuit pack.
PASS All of the firmware error counters were zero. Look at the results of other tests to
see if it is operating correctly.
1. See the MSS Error Actions Table at the end of the TAPE section.
Table 9-227. TEST #812 Disk Firmware Error
Counters Read and Clear Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page