DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-921HYB-LINE (Hybrid Line)

9
Hybrid Line Lamp Updates Test (#60)

For this test, the software lights the lamps on the terminal b ased on the status

record contained in the p rocessor. The lamp updates will r un only if the station is

in-service.

0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane bo ard is inserted.
1. Check to ensure that the board translations are correct. Use the list config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Table 9-354. TEST #60 Hybrid Line Lamp Updates Test
Error
Code Test
Result Description/ Recommendation
1 ABORT A request for a remote station lamp update aborted even though all internal
resources were correctly allocated.
1. Look in the error log for Error Type 18 (port busied out) for this port. If this
Error Type is present, release the port via the release port UUCSSpp
command or the release station extension command, and then run the
test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
2 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-353. TEST #59 Hybrid Line Remote Digital Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page