DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1355RING-GEN

9
Error Log Entries and Test to Clear Values
System Technician-Demanded T ests: Descripti ons
and Error Codes

Always investigate tests in the order p resented in the table below when

inspecting errors in the sys tem. By clearing error cod es associated with the

Analog Ring Generator Initialization

Test, for example, you may also clear errors

generated from other tests in the testing sequence.
Table 9-533. Analog Ring Generator Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test environment UU
1 Analog Ring Generator
Query (#118) MAJO
RON test environment UU r 3
Table 9-534. Multicarrier Cabinet
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive, ND = Non-destruc tive
Analog Ring Generator Initializati on Test (#117) X X ND
Analog Ring Generator Query Test (#118) X X ND
Battery & Battery Charger Query Test (#5) (a) X X ND
AC Power Query Test (#78) (b) X X ND
OLS Query Test (Carrier E) (#127) (c) X X ND
OLS Query Test (Carrier D) (#127) (c) X X ND
OLS Query Test (Carrier A) (#127) (c) X X ND
OLS Query Test (Carrier B) (#127) (c) X X ND
OLS Query Test (Carrier C) (#127) (c) X X ND
Emergency Transfer Query Test (#124) (d) X X ND
Cabinet Sensors Query Test (#122) (e) X X ND
External Alarm Lead Query Test (#120) (f) X X ND