9-1411SNC-BD (Switch Node Clock Circuit Pack)

9
SNC On-Board Test (#778)
This test is non-destructive.

This test queries the SNC circuit pac k for status of the background tests run

on-board. These backg round tests include an SNC on-b oard microcontroller test,

clock test, an SNC on-board Stratum 3 osc illator test, and TPN microcontroller

test.

FAIL The SNC circuit pack reported failures or retransmitted a cleared failure
message.
1. Check the error an d alarm logs for SNC-BD, SNC-LINK, or SNC-REF
entries. Use the display errors and display alarms commands with
category PNC. Fix any problems found by referring to the SNC Board,
SNC Link, or SNC Reference Error Log Entries tables in this section and
follow the associated repair procedures.
2. If no SNC-BD, SNC-LINK, or SNC-REF errors exist in the error and alarm
logs, retry the command.
PASS No problems are detected on the board.
0NO
BOARD No board was detected by the test.
1. Check that SNC boa rd is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNC should be reset
instead of reseating the c ircuit pac k. The reset board command should
almost never be used on an SNC. It may be necessary to use the reset
board command if the SNC circuit pack gets into a mode where it cannot
communicate with software. If an SNC with active errors and alarms is
reset, the errors and alarms may take a while to come back, therefore the
reset board command can mask real p roblems.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 9-552. TEST #777 Failure Audit — Continued
Error
Code Test
Result Description/ Recommendation