DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1942XXX-BD (Common Port Circuit Pack)

9
Error Log Entries and Test to Clear Values
Notes:
a. Error type 1 indicates the circ uit pack has stopp ed functioning or has been physically removed from the system. This error type does not app ly to ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is logged ap proximately 11 minutes after removal of the circui t pack or failure of the SAKI Sanity Test (#53).Table 9-720. Common Port Circuit Pack Maintenance Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test board UUCSS sh r 1
1(a) 0 Circuit pack removed
or SAKI Sanity T est
(#53)
MINOR ON
18(b) 0 busy-out board UUCSS WARNING OFF release board UUCSS
23(c) 0 None WARNING OFF
36 (d) 4368 none
125 (e) None MINOR ON
217 (f) 0 None WARNING ON
257 65535 Control Channel Test
(#52) MINOR ON test board UUCSS sh r 20
257 (g) Any None
267 (f) 0 None WARNING ON
513 (h) Any None MINOR ON test board UUCSS sh
769 (i) 4358 None
1025 (j) 4363 NPE Audit Test (#50) test board UUCSS l r 20
1281 (k) Ringing Application
Test (#51) MINOR ON test board UUCSS r 2
1538 (l) Any None WARNING/
MINOR ON
1793 (m) Neon Test (#220) MINOR ON test board UUCSS r 2
3840 (n) Any None
3999 (o) Any None